also owns KVAR Energy Savings Inc and the KVAR Unit.The KVAR Unit is
indeed the original ,that everyone's been talking about ,and what the
others so desperately wish they can conceive. The Kvar Unit is
distributed by Energy Boxx. The KVAR Unit has a five year warranty and
has a life span of 25 years.The KVAR Unit reduces your electrical
consumption by at least 10% and as much as 25%.The KVAR Unit comes in
single and 3 phase units 22-480 volts.
The KVAR Unit also surge protects your entire home agaist voltage
fluctuations and electrical storms.The KVAR Unit is UL Listed and CSA
approved, also the product is Energy Star
compliant.Please visit www.energyboxx.com for furhter information and
video news
reels of some of the coverage the KVAR Unit has been receiving.
To quote another poster:
1. As SQLit said major effect of increasing the power factor is only of
economic advantage if the utility meters the power factor and charges
for it. Not likely on residential.
2. Propaganda on reducing residential killo-Watt-hours (power) by about
12% IMHO is bullshit. With low power factor the Volt-Amps may be reduced
but not the power since power takes into account the phase angle between
voltage and current.
3. With a low power factor there would be some reduction in current and
thus some reduction in heat loss in wire. This would be quite low in
residential. Connecting the device at the service, as shown, will lower
the losses in the wires from the meter to the service, as short run of
large wire.
4. From what I saw in the patent application, conviently supplied by
Roger, the amount of correction is manually set with switches. If you
have one motor running and correct the power factor, the correction will
be wrong if you turn off the motor or add another motor (or turn off 1st
motor and turn on 2nd motor). Over correcting (when the 'motor' is
turned off) is also a problem.
bud--
Looks kike more snake oil. If you want lower bills, you need to do it the hard
way -- more efficient appliances and liberal use of the OFF switch.